UTILITY-GRADE MEGAWATT GENERATION
1250–1875 kVA
Industrial Diesel
Generators
Industrial diesel generator sets engineered for dependable performance, fuel efficiency and demanding operating conditions in the 1250–1875 kVA (1000–1500 kW) power class.
- ✓ 1250–1875 kVA continuous rating for heavy industrial and utility backup
- ✓ V-type multi-cylinder engine architecture with low operating costs
- ✓ Heavy-duty skid with internal anti-vibration isolators
- ✓ SCADA telemetry and automated bus synchronizing
NİYƏ SEER POWER
Real Enerji Tələbləri Üçün Yaradılıb
Digər Generator Seriyalarını Kəşf Edin
Fərqli güc diapazonları, komplektasiyalar və layihə tələbləri üçün digər dizel generator dəsti variantlarını kəşf edin.
Məhsul Spesifikasiyaları
Spesifikasiyaları yükləyin5 mühərrik brendinin XLSX faylları
| Generator Modeli | Əsas Güc (kW / kVA) | Ehtiyat Güc (kW / kVA) | Mühərrik Brendi | Mühərrik Modeli | Alternator Brendi | Tezlik (Hz) | Gərginlik (V) | Açıq Tip (U × E × H) (mm) | Açıq Tip Çəki (kq) | Səssiz Tip (U × E × H) (mm) | Səssiz Tip Çəki (kq) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SP-24WC | 24 / 30 | 26 / 32.5 | Weichai | WP2.3D33E200 | Leroy-Somer / SEER POWER | 50 / 60 | 220 / 230 / 380 / 400 / 415 / 440 / 480 | 1500 × 700 × 1050 | 510 | 2100 × 850 × 1160 | 830 |
| SP-30WC | 30 / 37.5 | 33 / 41.3 | Weichai | WP2.3D40E200 | Leroy-Somer / SEER POWER | 50 / 60 | 220 / 230 / 380 / 400 / 415 / 440 / 480 | 1570 × 700 × 1050 | 570 | 2100 × 850 × 1160 | 930 |
| SP-36WC | 36 / 45 | 40 / 50 | Weichai | WP2.3D48E200 | Leroy-Somer / SEER POWER | 50 / 60 | 220 / 230 / 380 / 400 / 415 / 440 / 480 | 1570 × 700 × 1050 | 590 | 2100 × 850 × 1160 | 930 |
| SP-50WC | 50 / 62.5 | 55 / 68.8 | Weichai | WP4.1D66E200 | Leroy-Somer / SEER POWER | 50 / 60 | 220 / 230 / 380 / 400 / 415 / 440 / 480 | 1900 × 925 × 1219 | 920 | 2300 × 1000 × 1250 | 1130 |
| SP-64WC | 64 / 80 | 70 / 87.5 | Weichai | WP4.1D80E200 | Leroy-Somer / SEER POWER | 50 / 60 | 220 / 230 / 380 / 400 / 415 / 440 / 480 | 2000 × 965 × 1467 | 1105 | 2300 × 1000 × 1250 | 1130 |
| SP-100WC | 100 / 125 | 110 / 137.5 | Weichai | WP6D132E200 | Leroy-Somer / SEER POWER | 50 / 60 | 220 / 230 / 380 / 400 / 415 / 440 / 480 | 2475 × 950 × 1600 | 1540 | (2520 + 650) × 1130 × 1300 | 1830 |
Bu cədvəldə Weichai mühərrikləri və Leroy-Somer və ya SEER POWER alternatorları nümunə olaraq göstərilmişdir. Digər mühərrik və alternator brendləri də mövcuddur. Tezlik, gərginlik və komponent seçimi hər bir layihə üçün fərdiləşdirilə bilər. Açıq tip üzrə boş xanalar həmin model üçün məlumatın olmadığını bildirir.
Bütün spesifikasiyaları görmək üçün üfüqi sürüşdürün.
GENERATOR SİSTEMİ
Standart Komplektasiya
CARİ SEÇİMDizel Mühərriki / Cummins
Brend Haqqında
Cummins G-Drive mühərrikləri generator tətbiqləri üçün xüsusi olaraq hazırlanmışdır. Çeşid ehtiyat və əsas enerji rejimləri üçün mühərrik ailələrini əhatə edir; seçilmiş seriya soyutma, yanacaq sistemi və idarəetməni müəyyən edir.
G-Drive inteqrasiyası
Cummins öz G-Drive mühərrik paketlərində modelə uyğun soyutma, hava təmizləyici və xidmət komponentlərini təqdim edir.
Layihə seçimi
Yekun mühərrik gücü, idarəetmə interfeysi və quraşdırma detalları layihə yükünə və təyinat yerinə uyğun yoxlanılır.
Məhsulun Üstünlükləri
-
Sübut olunmuş etibarlılıq və dözümlülük
-
Yüksək güc və güclü fırlanma anı
-
Optimallaşdırılmış yanacaq sərfiyyatı
-
Qlobal servis şəbəkəsi
Brend Haqqında
Perkins Electric Power engines cover generator-set applications from compact standby packages to larger industrial systems. Certified or fuel-optimised variants and electronic features vary by series.
Electric Power portfolio
Perkins presents a modular electric-power range with model-specific ratings, controls and service requirements.
Series boundary
Load acceptance, high power density and remote monitoring are used here only where the selected Perkins series documentation supports them.
Məhsulun Üstünlükləri
-
Electric Power engine
range
-
Certified variants by market
and series
-
Fuel-optimised variants by
model
-
Electronic management on
selected series
Brend Haqqında
Volvo Penta power-generation engines are designed for standby and prime duties where load acceptance, compact integration and service access matter. This site limits the approved application range to 50 to 500 kW.
Power-generation range
Volvo Penta describes power-generation engines with attention to efficiency, low noise, reliability and ease of service.
D8 series reference
Replaceable liners, piston cooling and accessible service points are specific to documented D8 configurations and are not applied to every model.
Məhsulun Üstünlükləri
-
Power-generation engine
range
-
Load acceptance for generator
duty
-
Compact installation on
selected platforms
-
Low fuel consumption on
selected models
Brend Haqqında
Weichai offers industrial power engines for backup, continuous and project-based generator applications. The selected platform determines the controls, cooling and service arrangement.
Industrial power platforms
Weichai lists industrial power engines by series, output and application rather than as one universal specification.
Package coordination
SEER POWER coordinates the engine, alternator, controller and enclosure around the confirmed duty and installation conditions.
Məhsulun Üstünlükləri
-
Industrial power engine
series
-
Backup and continuous-duty
options by model
-
Mechanical or electronic
control by series
-
Cooling and service layout
reviewed together
Brend Haqqında
SDEC publishes engine series for generator-set and industrial power applications. The control system, operating speed, cooling arrangement and rating depend on the selected series.
Series selection
SDEC generator-drive families are reviewed by operating speed, duty and the requirements of the destination market.
Configuration check
SEER POWER confirms the exact SDEC model and documentation before it is paired with the alternator, controller and enclosure.
Məhsulun Üstünlükləri
-
Generator-drive engine
series
-
Mechanical or electronic
control by model
-
Operating speed matched to
frequency
-
Cooling package selected by
series
Brend Haqqında
Baudouin PowerKit engines are developed for standby, prime and continuous-power generator applications. The applicable model, rating basis and cooling arrangement are confirmed for each project.
PowerKit platform
Baudouin presents PowerKit engine products for generator applications, with model-specific ratings and integration details.
Selected-series detail
High-pressure common rail, ECU control and air-to-air cooling are treated as selected-series details, not blanket claims for every PowerKit engine.
Məhsulun Üstünlükləri
-
PowerKit generator-drive
range
-
Standby, prime and continuous
options
-
High-pressure common rail on
selected series
-
ECU control on selected
series
Brend Haqqında
Yuchai publishes engine products and generator-drive series for power-generation applications. Fuel system, controls, rating and service layout vary with the selected model.
Generator-drive range
Yuchai engine selection is made by generator duty, operating speed and the output required by the project.
Model review
The final data sheet, cooling arrangement and service access are checked before the package is released.
Məhsulun Üstünlükləri
-
Dedicated generator-drive
series
-
Electronic control on selected
models
-
Generator-duty load response by
series
-
Cooling arrangement matched to
the model
Brend Haqqında
Ricardo engine options are considered for generator projects within the approved 24 to 400 kW site range. The exact manufacturer, model, rating and supporting documentation must be verified for each quotation.
Generator-power reference
Ricardo identifies engine products for land-generator and power-output applications, with the product page defining the documented model scope.
Evidence boundary
The approved SEER POWER range and final supply status remain subject to model-level confirmation before publication or quotation.
Məhsulun Üstünlükləri
-
Generator-power engine
options
-
Land-generator application
reference
-
Model-specific speed and
rating
-
Cooling arrangement verified by
model
Brend Haqqında
STAMFORD industrial alternators cover generator-set applications with model-specific windings, voltage and bearing configurations. AVR and excitation choices depend on the selected series.
Excitation choices
STAMFORD documents brushless alternators with self-excited and PMG-supported AVR arrangements on selected systems.
Model selection
Frame, winding, voltage, coupling and AVR are checked against the engine and the confirmed load profile.
Məhsulun Üstünlükləri
-
Brushless industrial alternator
construction
-
PMG excitation on selected AVR
systems
-
Three-phase sensing on selected
AVRs
-
Model-specific winding and
voltage
Brend Haqqında
Leroy-Somer alternators include industrial low-voltage ranges for standard and demanding generator applications. Excitation and AVR arrangements are selected by model.
Excitation systems
Leroy-Somer documentation describes AREP, AREP+ and PMG excitation arrangements on selected alternators.
Package matching
The alternator frame, winding, voltage, excitation system and coupling are matched to the confirmed generator package.
Məhsulun Üstünlükləri
-
Industrial low-voltage
alternator range
-
AREP and AREP+ excitation
options
-
PMG excitation on selected
models
-
Application-specific AVR
choices
Brend Haqqında
Marathon Electric alternators provide industrial brushless configurations with model-specific excitation, insulation and winding options. The exact frame and regulator are confirmed before production.
MagnaPlus range
Marathon documents MagnaPlus alternators with brushless construction, optional PMG, Class H insulation and reconnectable winding choices on selected models.
Application detail
The selected frame, AVR, voltage, pole configuration and load-response requirements are recorded in the project specification.
Məhsulun Üstünlükləri
-
Brushless MagnaPlus
alternators
-
Optional PMG on selected
models
-
Class H insulation on selected
models
-
12-lead reconnectable
options
Brend Haqqında
SEER POWER alternator configurations are factory-coordinated options for standard generator packages. The technical record identifies the selected voltage, winding, AVR, insulation and mechanical interface.
Configuration record
The alternator option is described through the project specification rather than a single universal model claim.
Evidence boundary
Availability, rating and factory test scope are confirmed in the quotation and supporting technical documents for each order.
Məhsulun Üstünlükləri
-
Voltage recorded in the project
specification
-
Winding selected for the
application
-
AVR selected for the load
profile
-
Insulation class recorded per
order
Brend Haqqında
Deep Sea Electronics provides generator controllers for manual or automatic start, mains-failure and advanced generator-control applications. Sensing, protection, I/O and communications depend on the selected module.
Controller functions
DSE modules combine generator and utility sensing with alarms, protection and configurable inputs and outputs.
Interface selection
The model, engine interface, monitoring points and communications are selected from the approved control narrative.
Məhsulun Üstünlükləri
-
Manual and automatic start
modes
-
Utility sensing for
mains-failure control
-
Engine alarms and shutdown
protection
-
Configurable inputs and
outputs
Brend Haqqında
ComAp InteliLite and related controllers support single-generator standby and prime-power applications with AMF, manual and remote-start operation. Model and accessory functions vary across the family.
Operating modes
ComAp positions InteliLite and related controllers for manual, automatic, AMF and remote generator operation.
Control narrative
The selected model, I/O list, transfer logic and communications are checked against the approved project sequence.
Məhsulun Üstünlükləri
-
AMF and manual-start
modes
-
Generator monitoring and
protection
-
Remote operation options by
model
-
Configurable control
logic
Brend Haqqında
SmartGen HGM-series controllers cover generator start, monitoring, protection and automatic mains-failure applications. Display, sensing, communications and expansion functions vary by model.
HGM controller family
SmartGen documents HGM controllers with automatic mains-failure, remote start and stop, monitoring and protection functions.
Model detail
USB, RS485, expansion I/O and display functions are checked against the selected SmartGen model.
Məhsulun Üstünlükləri
-
Automatic mains-failure
operation
-
Remote start and stop
-
Alarm and shutdown
protection
-
Electrical data
monitoring
Brend Haqqında
Fortrust controllers provide generator start, stop, monitoring and protection functions for standard control panels. Measurements, communications and configurable functions depend on the selected model.
Generator control
Fortrust product materials describe automatic mains-failure, utility detection and transfer functions on selected controller families.
System scope
Paralleling, grid connection and cloud monitoring are treated as selected-system functions that require model-level confirmation.
Məhsulun Üstünlükləri
-
Automatic mains-failure
control
-
Utility detection and transfer
functions
-
Generator monitoring and
protection
-
Configurable control functions
by model
Brend Haqqında
SEER POWER circuit-breaker configurations are coordinated with the generator output and the project distribution system. The selected frame, pole arrangement, trip functions and accessories remain quotation-confirmed.
Project coordination
The breaker frame, rating and protection arrangement are checked against the selected generator output and distribution design.
Protection record
Pole count, trip settings, isolation and accessory scope are recorded for the confirmed project configuration.
Məhsulun Üstünlükləri
-
Generator-output protection
coordinated
-
Frame and rating confirmed per
project
-
Pole arrangement selected for
the distribution
-
Trip functions specified for
the circuit
Brend Haqqında
SEER POWER base frame and fuel-tank options are coordinated with the selected generator package. Dimensions, mounting, tank arrangement and service clearances remain project-confirmed.
Package integration
Frame dimensions, mounting points and access clearances are set against the selected engine, enclosure and site layout.
Fuel arrangement
Tank capacity, connections and runtime are reviewed against the duty, installation conditions and project requirements.
Məhsulun Üstünlükləri
-
Package dimensions
confirmed
-
Mounting and anti-vibration
points planned
-
Integrated fuel-tank
arrangement
-
Lifting access included in the
layout
Brend Haqqında
The Starting Battery System is included as a standard SEER POWER configuration item. The final starting arrangement is matched to the selected generator model and recorded in the project configuration.
Starting arrangement
The selected starting arrangement is recorded against the engine model in the project configuration.
Service access
Tray position, terminal protection and cable routing are checked during package review.
Məhsulun Üstünlükləri
-
Engine-matched starting
arrangement
-
Capacity and quantity recorded
by model
-
Secured tray with protected
terminals
-
Service-accessible cable
routing
Brend Haqqında
SEER POWER sound-attenuated enclosure options are coordinated with the generator package, airflow, service access and confirmed site brief. Acoustic treatment, finish and dimensions remain project-confirmed.
Acoustic and airflow review
Attenuation materials, ventilation openings and hot-air discharge are coordinated with the selected generator set.
Service access
Doors, lifting access, finish and clearances are checked against routine maintenance and the installation site.
Məhsulun Üstünlükləri
-
Acoustic treatment matched to
the target
-
Weather protection for the
installation
-
Service doors for routine
maintenance
-
Ventilation sized to the
generator set
Optional Configurations
Custom Sound-Attenuated Enclosure
An upgrade to the standard enclosure, with acoustic treatment, airflow, access or finish adapted to the confirmed site brief.
Trailer-Mounted
Mobile power package for temporary projects and changing job sites.
Parallel / ATS
Scalable power with synchronization and automatic transfer control.
Containerized
Containerized enclosure for weather protection and site installation.
Voltage Options
Voltage configurations tailored to distribution and application requirements.
Main Applications for 30–125 kVA Industrial Diesel Generators
Typical fits center on compact standby and light project loads. Final selection follows the connected load and site conditions.
Compact standby power for essential circuits in small shops, restaurants and low-rise retail sites.
Typical applications for this power range, subject to the confirmed load and project requirements.
Single-site retail, food service and small commercial premises.
Confirm the essential load list, transfer method, installation space and acoustic target.
Standby or extended-runtime support for one base station or a small equipment shelter.
Typical applications for this power range, subject to the confirmed load and project requirements.
One tower, repeater site or compact telecom equipment room.
Review rectifier load, fuel autonomy, automatic start, remote signals and service access.
Temporary power for site offices, light tools, pumps and smaller project loads.
Typical applications for this power range, subject to the confirmed load and project requirements.
Small construction sites, temporary offices and light plant.
Check starting load, relocation needs, dust and weather protection, and fuel access.
Backup power for small workshops, essential circuits or one light production process.
Typical applications for this power range, subject to the confirmed load and project requirements.
Light manufacturing, repair workshops and selected production loads.
Separate motor loads from essential circuits and confirm transfer and ventilation needs.
Power for one irrigation pump, greenhouse systems or essential livestock support.
Typical applications for this power range, subject to the confirmed load and project requirements.
Single-pump irrigation, poultry, greenhouse and seasonal field work.
Confirm pump starting current, runtime, weather exposure and refueling access.
Standby power for essential services in low-rise offices and small business premises.
Typical applications for this power range, subject to the confirmed load and project requirements.
Lighting, security, IT and selected building services.
Prioritize essential circuits and review ATS sequence, acoustic limits and available space.
TEZ-TEZ VERİLƏN SUALLAR
Çatdırılma müddəti seçilmiş gücdən, mühərrik brendindən, korpus tipindən, gərginlik və idarəetmə tələblərindən asılıdır. Standart komplektasiyalar texniki təsdiqdən sonra planlaşdırılır; xüsusi layihələr əlavə mühəndislik və istehsalat vaxtı tələb edir. Dəqiq qrafik kommersiya təklifində göstərilir.
Bəli. Mühərrik, alternator, gərginlik, tezlik, korpus, yanacaq çəni, kontroler, ATS, paralel işləmə sistemi, qoşqu strukturu, rəng və brend tərtibatı layihə və hədəf bazar tələblərinə uyğun konfiqurasiya edilə bilər.
Quraşdırma çertyojları, elektrik sxemləri, istismara vermə təlimatları, uzaqdan texniki yardım və dövri xidmət tövsiyələri təqdim edirik. Layihə yerindən və xidmət həcmindən asılı olaraq sahədə dəstək də təşkil edilə bilər.
Mövcud sənədlərə texniki pasportlar, ümumi yerləşmə çertyojları, elektrik sxemləri, istismar təlimatları, zavod sınaq protokolları, qablaşdırma siyahıları və tətbiq olunan sertifikatlar daxildir. Yekun sənəd paketi hər layihə üçün təsdiqlənir.
SINAQDAN KEÇİB. ETİBARLIDIR. TƏHVİL VERİLİB.
Zavod sınaqlarıSənədləşdirilmiş yoxlama və sınaq prosedurları
Yük stendi sınaqlarıLayihəyə uyğun sınaq həcmi
Koordinasiyalı çatdırılmaGöndərilmədən əvvəl qablaşdırma və sənədlər təsdiqlənir
24/7 Texniki Dəstəkİstismara vermə və əməliyyat üçün uzaqdan yardım